    Tramex 110mm Relative Humidity Sensor

    REUSABLE AMBIENT RH PROBE FOR USE WITHIN BUILDING STRUCTURE

    The Tramex Relative Humidity Probes are the most advanced, resilient and re-usable RH probe on the market today, allowing the user to evaluate moisture conditions within the building structure. The different lengths and thicknesses make them ideal for use by Flood and Water Damage Restoration as well as Building Survey professionals. The probes, which house the latest Hygro-i2 technology, measure Relative Humidity, Temperature, Dewpoint temperature and grains per pound humidity ratio. The probes can be used for the evaluation of moisture conditions of wall and cavity structures as well as ambient air conditions within the building envelope. The speed and accuracy of the Tramex Hygro-i2® probes set them apart from all other RH probes on the market. The confidence in knowing you are testing with the best and fastest RH probe brings reliability and peace of mind to a whole new level.

    Product Order Code: RHP-SW (with Din Connection for use with CMEX2 and MRH3)

    Product Order Code: RHP-SW-B (with Bayonet Connection for use with Feedback Datalogger RHTX and CMEX5)

     
    Fetaures:
    • Fast Acclimation and Temperature response time.
    • Proven robustness, Durable and Reusable.
    • Best in class accuracy and reliable, even at high RH >90%.
    • Measures giving in situ relative humidity and ambient RH, temperature, dew point temperature & grains per pound.
    • Relative Humidity range: 0% to 100%
    • Temperature Range: -40°C to 80°C
    • Best temperature accuracy of +/-0ºC to 90 ºC
     
    Relative Humidity Sensor Specifications:
    Range:         0 to 100%RH
    Accuracy:      0% to 99%RH ±2.0%RH (@ 25ºC)
    Resolution:   0.1% over the complete range
    Drift:  <0.25%RH per year
     
    Temperature Sensor Specifications:
    Range:         -40ºC to 125ºC
    Accuracy:      ±0.1°C        
    Sensor Protection:  PTFE Film protects sensor opening from water & dust
    Drift:            < 0.03ºC per year
    NIST traceable.       (National Institute of Standards and Technology)